Connection

The device cannot be found or the port does not open

Check that the serial port is not occupied by another tool, that the baud rate matches the target configuration, and that the firmware contains the XCP slave (emXCP) and is running. USB-serial adapters should be tested with their vendor driver installed.

Can I evaluate the software without any hardware?

Yes. The package includes the emwdemo simulated target and demo projects. With a virtual serial port pair (for example com0com) installed, the demo works out of the box — variables, trend curves and value write-back included.

Acquisition

DAQ starts but no values arrive

Confirm the variables were resolved from the correct ELF file (matching the firmware actually running on the board), that the measurement list is not empty, and that the target answers the connect command. The status bar reports protocol errors such as timeouts.

How do I choose the sample rate?

Scope refresh periods of 5 / 10 / 20 / 50 / 100 ms are selectable. Faster rates increase bus load; if the link saturates, reduce the number of channels first, then the rate.

Waveforms

The Scope stays empty while Watch shows values

Scope needs DAQ to be running and variables to be assigned to channels. Start acquisition, then drag variables into the Scope channel list.

Why do measurements differ slightly from another tool?

Check the sample rate and the exact variable scaling (IQ fixed-point format, factor / offset). Every point can be traced back to its raw sample in the detail view.

Data & projects

Where are projects and recorded data stored?

In your local workspace folder: the workspace is a .workspace file, projects are .project files and recordings are .xcpdata files. Copying the whole workspace folder migrates the environment.

Which export formats are available?

Basic exports curves as txt / csv. Commercial recording supports native XCPData plus standard MDF4 and CSV, and comparison results can be exported as a single-file HTML report.

Licensing

How do I import a license?

Either use the menu Help → Import License and select the .lic file, or place emeye.lic next to EmeyeStudio.exe — it is loaded automatically on startup. The status bar shows the unlocked tier and licensee.

What is the difference between Basic and Commercial?

Basic is free and covers Watch monitoring, trend curves, curve export (txt / csv), variable addresses, the lightweight frame protocol and project management — download it from the download page. Commercial adds Scope live DAQ, firmware loading, long recording, offline analysis, the algorithm library, comparison reports and regression test cases, licensed as Target, Recorder or test-case library tiers, with a 30-day full-feature trial.

Does the Basic edition expire?

No. It is free and stays usable; data you collected remains available for learning and evaluation.

How do I request a commercial trial?

Email emeye-eric@foxmail.com with your use case, target MCU and contact details. We reply with a private download link and a 30-day trial license.

The license stopped working after changing hardware

Licenses are machine-bound. After replacing the computer, mainboard or network adapter, send us the new machine code — we reissue the same tier free of charge after verification.

Still stuck?

Send the software version, the error message and the steps you took to emeye-eric@foxmail.com.